The 60000 BTU Under/Floor Ceiling Split from Chigo Air-Conditioning is best suited for home, office and industrial use. This aircon will work optimal in rooms and areas with a floor size of up to 100m². Our franchises, agents and dealers are all highly trained professionals and will also be able to assist you with the installation.
Feel free to request a quote or contact us for expert advise.
Type of Unit | UNDER/FLOOR CEILING SPLIT | ||
---|---|---|---|
Model | CUA-60HR1 | ||
Indoor Power Supply | V-Ph-Hz | 220~240/1/50 | |
Cooling | Capacity | Btu/h | 55000 |
kW | 16 | ||
Input | W | 260 | |
Rated current | A | 1.15 | |
EER | W/W | 2.68 | |
Heating | Capacity | Btu/h | 60000 |
Kw | 17.6 | ||
Input | W | 260 | |
Rated current | A | 1.15 | |
COP | w/w | 2.64 | |
Indoor Fan Motor | Model | YDK-110-59LD-4P17 + YDK-110-59LD-4P17 | |
Input | W | 260 | |
Capacitor | uF | 3+3 | |
Speed (Hi/Med/Low) | r/min | 1310/1139/1016 | |
Indoor Coil | Number of Rows | 2 | |
Tube Pitch (a) x Row Pitch (b) | mm | 25 x 21.65 | |
Fin Spacing | mm | 1.5 | |
Fin Type | Hydrophilic | ||
Tube Outside Dia and Type | mm | 9.52 Inner grooved | |
Coil length x height x width | mm | 1360 x 250 x 43.3 | |
Number of Circuits | 5 | ||
Indoor Airflow (High speed) | m³/h | 2300 | |
Indoor noise level | dB(A) | 48~57 | |
Indoor Unit | Dimension (W x D x H) Body | mm | 1670 x 247 x 680 |
Packaging (W x D x H) Body | mm | 1750 x 325 x 770 | |
Net/Gross weight Body | Kg | 47/54 | |
Max Pressure | MPa | 4.5 | |
Refrigerant | Type | R410a | |
Refrigerant Piping | Liquid Side / Gas Side | mm | 9.52/19.05 (3/8 x 3/4) |
Drainage Pipe | mm | DN25 | |
Standard Controller | Standard controller | ||
Operation Temperature | °C | 16~32 | |
Ambient Temperature | Cooling | °C | 18-50 |
Heating | °C | -7~24 | |
Application Area | m² | 60~105 | |
Model | COU-60HSR1 | ||
Outdoor Power Supply | V-Ph-Hz | 380~415/3/50 | |
Cooling | Capacity | Btu/h | 55000 |
Kw | 16 | ||
Input | W | 5700 | |
Rated current | A | 10 | |
Heating | Capacity | Btu/h | 60000 |
Kw | 17.6 | ||
Input | W | 5800 | |
Rated current | A | 10.2 | |
Max Input Consumption | W | 6600 | |
Max Current | A | 11.8 | |
Starting current | A | 85 | |
Compressor | Model | QXAS-H64SN330 | |
Type | Rotary | ||
Brand | Landa | ||
Capacity | Btu/h | 58300 | |
Input | W | 5450 | |
Rated current (RLA) | A | 10.6 | |
Locked rotar (LRA) | A | 85 | |
Thermal protector | Internal | ||
Capacitor | uF | / | |
Refrigerant Oil | ml | 1700 | |
Outdoor Motor Fan | Model | YDK-60-6P3-2 | |
Input | W | 170*2 | |
Capacitor | uF | 4*2 | |
Speed | r/min | 780 | |
Outdoor Coil | Number of rows | 2 | |
Tube Pitch (a) x Row Pitch (b) | mm | 25 x 21.65 | |
Fin spacing | mm | 1.6 | |
Fin type | Hydrophilic | ||
Tube outside dia. and type | mm | 9.52 Inner grooved | |
Coil length x height x width | mm | 810 x 1275 x 43.3 | |
Number of circuits | 7 | ||
Outdoor Airflow (High speed) | m³h | 6100 | |
Outdoor noise level | dB(A) | 60 | |
Outdoor Unit | Dimension (W x D x H) | mm | 911 x 400 x 1335 |
Packaging (W x D x H) | mm | 964 x 402 x 1445 | |
Net/Gross weight | Kg | 101/111 | |
Refrigerant | Type | g | R410a/4000 |
Throttle Part | Capillary | ||
Design Pressure | MPa | 4.0/1.2 | |
Max Pressure | MPa | 4.5 | |
Connecting Wiring | Outdoor power supply | Separated | |
Power wiring | mm | 5 x 2.5 / 3 x 1.0 | |
Signal wiring | mm | 3 × 0.75 | |
Refrigerant Piping | Liquid Side / Gas Side | mm | 9.52 /19.05 (3/8 x 3/4) |
Max Pipe Length | m | 50 | |
Max High Drop | m | 30 | |
Ambient Temp | Cooling | °C | 18-50 |
Heating | °C | -7~24 |