The 24000 BTU Inverter Ceiling Cassette from Chigo Air-Conditioning is best suited for home and office use. This energy-saving aircon will work optimal in rooms with a floor size of up to 40m². Our franchises, agents and dealers are all highly trained professionals and will also be able to assist you with the installation.
Feel free to request a quote or contact us for expert advise.
Type of Unit | INVERTER CEILING CASSETTE | ||
---|---|---|---|
Model | CCA-24HVR1 | ||
Indoor Power Supply | V-Ph-Hz | 220~240/1/50 | |
Cooling | Capacity | kW | 3.5-8.0 |
Input | W | 600-3000 | |
Rated current | A | 2.5-13 | |
EER | W/W | 3.26 | |
SEER | W/W | 6.1 | |
Heating | Capacity | Btu/h | 4.5-8.5 |
Input | W | ..... | |
Rated current | A | 5.5-11 | |
COP | W/W | 3.72 | |
SCOP | W/W | 4.0 | |
Energy rate | Cooling | A++ | |
Energy rate | Heating | A+ | |
Max. power input | W | 3200 | |
Max. current input | A | 14 | |
Indoor Fan Motor | Model | DR-310-60Q-8 | |
Brand | Panasonic | ||
Power Input | W | 60 | |
Capacity | uF | - | |
Speed (Hi/Med/Low) | r/min | 850/790/600 | |
Insulation class | E | ||
Indoor Coil | Number of Rows | 2 | |
Tube Pitch (a) x Row Pitch (b) | mm | 21 x 13.37 | |
Fin Spacing | mm | 1.45 | |
Fin Type | Hydrophilic | ||
Tube Outside Dia. and Type | mm | Φ7 Inner grooved | |
Coil length x height x width | mm | 2000 x 168 x 26.74 | |
Number of Circuits | 8 | ||
Indoor Airflow (High speed) | m³/h | 1100/1000/850 | |
Indoor noise level | Power level | dB(A) | 56-63 |
Pressure level | 43/46/49 | ||
Indoor Unit | Dimension (W x D x H) Body | mm | 840 x 840 x 230 |
Panel | mm | 950 x 950 x 50 | |
Packaging (W x D x H) Body | mm | 920 x 920 x 265 | |
Panel | mm | 1030 x 1030 x 105 | |
Net/Gross weight Body | Kg | 25/30 | |
Panel | Kg | 5.4/8.0 | |
Max Pressure | MPa | 4.2 | |
Refrigerant | Type | R410A | |
Refrigerant Piping | Liquid Side/Gas Side | mm | 9.52/15.55 (3/8 x 5/8) |
Drainage Pipe | mm | DN25 | |
Standard Controller | Standard controller (wired controller for option) | ||
Operation Temperature | °C | 16~32 | |
Ambient Temperature | Cooling | °C | -15~50 |
Heating | °C | -15~30 | |
Application Area | m² | 28-50 | |
Model | COU-24HDR1 | ||
Outdoor Power Supply | V-Ph-Hz | 220~240/1/50 | |
Cooling | Capacity | Kw | 3.5-7.0-8.0 |
Input | W | 540-2940 | |
Rated current | A | 2.2-12.7 | |
Heating | Capacity | Kw | 4.5-7.7-8.5 |
Input | W | 1440-2540 | |
Rated current | A | 5.2-10.7 | |
Compressor | Model | TNB220FFEMC | |
Type | DC/Twin-rotary | ||
Brand | Mitsubishi | ||
Frequency range | Hz | 12-120 | |
Capacity | W | 6940 | |
Input | W | 2150 | |
Rated current (RLA) | A | 8.7 | |
Refrigerant Oil | ml | 520 | |
Outdoor Fan Motor | Model | DR-310-72-8 | |
Brand | W | Panasonic | |
Power Output | W | 72 | |
Speed | r/min | 800 | |
Insulation class | E | ||
Outdoor Coil | Number of rows | 2 | |
Tube Pitch (a) Test Row Pitch | mm | 25 x 21.65 | |
Fin spacing | mm | 1.8 | |
Fin type | Hydrophilic | ||
Tube outside dia. and type | mm | 9.52 Inner grooved | |
Coil length x height x width | mm | 850 x 800 x 43.3 | |
Number of circuits | 4 | ||
Outdoor Airflow (High speed) | m³h | 5000 | |
Outdoor noise level | Power level | dB(A) | 50-54 |
Pressure level | 54 | ||
Outdoor Unit | Dimension (W x D x H) | mm | 958 x 392 X 843 |
Packaging (W x D x H) | mm | 1025 x 430 X 960 | |
Net/Gross weight | Kg | 59/69 | |
Refrigerant | Type | g | R410a/2400 |
Throttle Part | EXV | ||
Design Pressure | MPa | 4.4/1.1 | |
Max Pressure | MPa | 3.8 | |
Connecting Wiring | Power wiring | mm | 3 x 2.5 |
Signal wiring | mm | 4 x 2.5 | |
Refrigerant Piping | Liquid Side/Gas Side | mm | 9.52/15.88 (3/8 x 5/8) |
Max Pipe Length | m | 20 (50) | |
Max High Drop | m | 10 (25) | |
Ambient Temp | Cooling | °C | -15~50 |
Heating | °C | -15~30 |